Overview
The Johnson Controls M9335-HGA-2 is a high-performance electric non-spring return actuator engineered to provide precise control of dampers and valves in commercial and industrial HVAC systems. It features automatic signal input detection, allowing it to automatically recognize on/off, floating, and proportional control signals. Designed for direct mounting without requiring damper linkage, it operates at a constant runtime independent of torque and includes electronic stall detection to protect against overloads.
Features
- Automatic Signal Input Detection: Automatically recognizes input signals for on/off, floating, and proportional control.
- Direct-Coupled Design: Configured for direct mounting with a universal clamp, eliminating the need for a damper linkage or crankarm.
- Brushless DC Motor: Microprocessor-controlled motor provides constant runtime independent of torque and reduces wear for a longer lifecycle.
- Electronic Stall Detection: Protects the actuator from overload at all angles of rotation without the need for mechanical end switches.
- Self-Calibrating Input Signal: Automatically adjusts the stroke when an end stop is changed, eliminating complex calibration procedures.
- Halogen-Free Cable: Equipped with a 48-inch halogen-free cable suitable for strict fire safety standards.
Specifications
- Supply Voltage: 24 VAC (19.2 to 28.8 VAC) at 50/60 Hz or 24 VDC (21.6 to 26.4 VDC)
- Torque Rating: 310 lb-in (35 N·m)
- Power Consumption: 6.4 VA running (AC), 2.2 W running (DC)
- Control Signals: On/Off, Floating, or Proportional (0(2)–10 VDC, or 0(4)–20 mA with field-furnished 500 ohm resistor)
- Feedback Signal: 0(2) to 10 VDC
- Running Time: 150 seconds
- Enclosure Rating: NEMA 5 / IP54
- Ambient Operating Temperature: -22°F to 140°F (-30°C to 60°C)
Applications
- Damper actuation in commercial and industrial HVAC systems.
- Valve control utilizing optional mounting kits, such as the VG1000 series valves.
- Air handling units (AHUs), fan coil units, and ventilation systems.
- Environmentally sensitive or code-restricted installations requiring low-smoke, zero-halogen (LSZH) wiring compliance, such as schools, hospitals, and data centers.
364-02001 Siemens 2-Way Normally Closed Brass Valve with SAS61.03U Actuator
HF-02 Hankison Filter Element (5005533)
B208+LFX24-SR US Belimo 1/2" 2-Way Characterized Control Valve, Cv 0.46, Fail-Safe 24V
025 32557 000 York Fan
144704 Model FPC-1000 McDonnell & Miller Low Water Cut Off
025-39806-000 York Capacitor
B209+LFX24-SR US Belimo 1/2" 2-Way Characterized Control Valve, Cv 0.8
LGB22.330A17 Siemens Burner Control
TJ-6382D-G58 Johnson Controls High Accuracy RTD Temperature Transmitter, 5.93" Probe, NIST
EPP301LCD Schneider Electric Pressure Sensor
024 42910 022 York Motor (ECTM3611T-G-AO)
DP1402X5U11C Johnson Controls Differential Pressure Transducer
006737F Raypak
1EF003LF Bell & Gossett Series e-60 Pump
025-53539-020 York Contactor
AGM410490550 Siemens Wiring Base
L25201 Bell & Gossett Oil Tube
59-497-080R Fireye Cable Assembly 


Reviews
There are no reviews yet.