VF-2213-536-9-65 Schneider Electric / TAC DuraDrive Valve Assembly – 2-Inch Spring-Return Ball Valve, 2-Way, 24V
2″ 2-Way, Floating, SR, N.O., 24V, 35 lb-in, 70 PSI, w/MF40-7043
Product Overview
The VF-2213-536-9-65 is a complete valve + actuator assembly in the TAC DuraDrive 2000 Series. It’s a 2-inch, 2-way spring-return ball valve with normal open fail position, designed for control of hot water or chilled water in HVAC applications. The assembly uses a 24V spring-return actuator (MA40-7043 type), capable of producing 35 lb-in torque and holding a close-off pressure of about 40 PSI. Engineered for reliable performance and easy installation, this valve assembly is ideal for systems that require dependable on/off or floating control with automatic return.
Specifications
| Specification | Details |
|---|---|
| Model / Series | VF-2213-536-9-65, TAC DuraDrive 2000 Series |
| Valve Type | Ball valve, 2-way, spring-return |
| Valve Size | 2-inch |
| Fail Position / Normal State | Normally Open (spring return to open when actuator de-energized) |
| Actuator Type | MA40-7043 spring-return electric actuator, 24V |
| Torque Output | 35 lb-in |
| Close-off Pressure | Approx. 40 PSI |
| Control Signal / Operation | Two-position ON/OFF or floating control via actuator |
| Application Media / Fluids | Hot water, chilled water, or other HVAC fluids (glycol mixes as specified) |
| Usage Typical In | Air handling units, zone valves, coils, and reheat & economizer systems |
| Benefits / Features | Durable ball valve design, compact assembly, automatic return |
Features & Benefits
-
Built-in spring return ensures the valve defaults to open when power is removed, supporting fail-safe operation.
-
The 35 lb-in torque actuator provides enough force to handle full static pressure across the valve without sticking.
-
24V power option aligns with standard HVAC control systems.
-
Compact ball valve design reduces leakage and provides quick response.
-
Close-off pressure of 40 PSI gives good margin for low/medium pressure HVAC pipelines.
Applications
-
Zone control for hot water or chilled water systems in commercial or industrial buildings.
-
Reheat coils or secondary boilers requiring fail-open behavior for safety or comfort.
-
Air handling units, fan coil units, or duct-mounted ball valves.
-
Retrofits of older TAC or Schneider electric systems using VF-series valves.
Installation & Maintenance Notes
-
Ensure power supply is 24V as required by the actuator; wrong voltage will damage actuator or impair operation.
-
Mount the valve assembly with proper support; the weight of actuator + valve may stress pipe fittings.
-
Maintain actuator and linkage clear of debris to prevent interference in movement.
-
Periodically check for valve leakage around the seat, especially when using glycol or treated water.
Warranty & Quality Assurance
-
OEM TAC / Schneider Electric standard warranty applies when installed and operated per specifications.
-
Manufactured to match TAC DuraDrive 2000 Series quality for durability and performance.
Related Products
-
Other VF-2213 series valve-actuator assemblies in various sizes (1-inch, 1½-inch, etc.)
-
VS- or VA-series equivalents for proportional or two-position control requirements
-
Replacement actuators, valve bodies, or trim kits for VF-series parts