The Veris PW2LX05S Pressure,Wet,2,Nema 4,LCD,0-250PSID
SPECIFICATIONS
| Display Type | : | LCD |
| Mounting | : | Panel |
| Pressure Measurement Range | : | 0 – 25 psi (0 – 1.7 bar) | 0 – 50 psi (0 – 3.5 bar) | 0 – 100 psi (0 – 7 bar) | 0 – 250 psi (0 – 17 bar) |
| Output Specifications | : | 4 – 20 mA |
| Application | : | Pump and Compressor Differential Pressure | Chiller Differential Pressure Monitoring |
| Application Zone | : | Plant Room |
| Burst Pressure | : | 1,250 psi (85 bar) |
| Calibration Certificate | : | No |
| Dimension Depth | : | 2.2″ (56 mm) |
| Dimension Height | : | 4″ (102 mm) |
| Dimension Width | : | 5.8″ (147 mm) |
| Display Size | : | 0.7″ x 1.4″ (17 mm x 36 mm) |
| Electrical Wiring | : | 2-wires (loop-powered) |
| Enclosure Material | : | Powder Coated Aluminium |
| Fitting Material | : | Stainless Steel |
| Fitting Size | : | 1/ 8” NPT |
| Fitting Type | : | Female |
| IP Protection | : | IP65 (NEMA 4) |
| Measurement Type | : | Differential Pressure |
| Model | : | PW2LX05S |
| Outputs | : | Analog output |
| Product Type | : | Sensor |
| Range | : | PW2 |
| Brand | : | Veris |
| Medium | : | Water |
| Product Certification | : | CE |
| Pressure Measurement Accuracy | : | Range A, B and C: ±1% of F.S. Range D: ±2% of F.S. |
| Supply Voltage DC Range | : | 12 – 24 VDC |
| Operating Current | : | 29 mA |
| Operating Humidity | : | 0 – 90% RH, non-condensing |
| Operating Temperature | : | 14 – 130 °F (-10 – 55 °C) |
| Standards EMC | : | EN 61000-6-1 |
| Warranty | : | 5 years |
FEATURES
The PW2 series 2-wire, 4 to 20 mA wet pressure transducers incorporate microprocessor profiled sensors for exceptional accuracy and reliability. Easy to use and designed to provide exceptional installation savings, the PW2 series is ideal for measuring pressure across pumps, filters, heat exchangers, compressors and other non-corrosive wet media applications.
- The jumper-selectable output switch for normal (4 to 20 mA) or reverse (20 to 4 mA) operation provides application flexibility
- Rugged, die-cast enclosure provides NEMA 4 sealing
- Selectable differential units: psid or bard
- Dual sensor design for improved overpressure tolerance, eliminates the requirement for a bypass valve assembly in most applications
- Jumper-controlled electronic surge dampening for high stability
- Pushbutton zero calibration – no trim pots to adjust, maintain accuracy and reduce callbacks with automatic zero calibration
- 2-wire transmitter output
- User-selectable output
- 2 times of maximum full scale range proof pressure
- 5 times of maximum full scale range burst pressure